Back To Main Page PUBLCATIONS BY SERGIO FEITOZA 

   

 

ENGLISH: The free articles published by me, Sergio Feitoza, intend to help small companies. Such ones generate most of jobs in the world. The idea is to improve knowledge and to show opportunities in the area of equipment for power low-cost substations.

 
 

PORTUGUES: Os artigos gratuitos publicados por mim, Sergio Feitoza, pretendem ajudar pequenas empresas. Tais empresas geram a maioria dos empregos no mundo. A idéia é aprimorar conhecimentos e mostrar oportunidades na área de subestações de baixo custo.



IN ENGLISHEspañol

FREE BOOK “Renewable Energy + Environmental Education to try to save the Planet (About Energy Transition, H2 Green, Hydrogen and ....)”


IEC61439-1: MISSING OVERLOAD TESTS for ROLLING-MILLS & OTHER INTERMITENT LOADS?
OVERLOAD TESTS FOR FUSES IN ROLLING-MILLS" - S. F. Costa, L.P. Rangel, R. G. Bastos  -- “ICEFA - International Conference on Fuses and Applications"  Nottingham-UK




Low voltage circuit-breakers: a great opportunity for new developments



SHORT CIRCUIT CURRENTS FORCES:    solutions for electric panels / busbars & MHD propulsion systems


A SUCCESSFUL LPC POWERCENTER SWITCHGEAR DEVELOPMENT – 6300A – 100 kA -690V
(by IEC 61439-1&2 plus internal arc test 100kArms + seismic tests)

Need a  High Power Lab for switchgear R&D ?





IEC62271-307 English
IEC62271-307 Portugues
Old Tables for busbars
Antigas Tabelas para barramentos
Video  Video Video Fusiveis na Janela



Artigo Fusiveis na Janela
Video Fuses in the window



Artcle Fuses in the window

Resposta da IEC sobre o número de aplicações em testes de arco interno de painéis de baixa tensão.   (IEC 61641)


Number of shots in low voltage switchgear INTERNAL ARC tests.  Read the IEC answer about number of shots (interpretation of IEC 61641)


LV CIRCUIT BREAKER       POWER    DISSIPATION :   

defines LV switchgear cost.    Choosing a brand ...

I

TTable 6 of IEC 61439-1:   QUESTION to CERTIFIERS & TESTING LABORATORIES:

-- What temperature rise limits, in bar/breaker connections, to use when approving or certifying low voltage switchgear?

-- reasonable to issue test reports without a statement “pass/fail”?

-- New test method (many sources) is more expensive than previous 

  If previous is not good, retest new panels of old designs?


 enabling real savings of Planet resources

Seismic Tests
Aluminum instead of copper
Stimulating Innovations and ideas to developers and designers via TRAINING
Como estimular a industria eletrica brasileira ?
Metal foam patent by Sergio
f
Why are the world's big manufacturers working hard on testing simulations
Why are the world's big manufacturers working hard on testing simulations
REDUCING MATERIALS WASTE IN THE ELECTRIC INDUSTRY by  using the power of TESTING SIMULATIONS  

  RETROFITTING   of   IEC 62271 & IEC61439 products a great business for electric panels assemblers 

 

 

 
Transformers Fires and Explosion Standard - Suggestion to IEC (from NBR8222)

 

 
Seeding R&D ideas
180+ posts by Sergio Feitoza Costa
Fires and explosions in power transformers
Suggestions to SC32A for next revision  With a world comparison of prices & quality of distribution services)  IEC 60282-2






 

ENVIRONMENTAL EFFICIENCY CERTIFICATE of electric products . ( kG / MVA ) The draft of a world-wide technical standard

 

TEMPERATURE RISE: A GUIDE to LEARNING to DESIGN     MV SWITCHGEAR (IEC62271), LV SWITCHBOARDS (IEC61439) & BUSWAYS

 

Bare Connection 50K to 60K

 

Você ainda usa as antigas tabelas de barras ?

 
Melhor se for prateado  

Better Silvered than Bare

 

WHY NOT USING OLD TABLES of BUSBARS amperes ??? 

 



HV Circuit Breaker Resistance as seen from terminals

 
2022: Creating development, employment & income in developing countries via electric industry (a real case example ).
 
IEC 60282-2 - High-voltage fuses - Part 2: Expulsion Fuses A suggestion to IEC - SC32A considering the extension of the validity of type test reports  
(Read first ) TEMPERATURE RISE: A GUIDE to LEARNING to DESIGN MV SWITCHGEAR (IEC62271), LV SWITCHBOARDS (IEC61439)& BUSWAYST
 
   
USE FREE SwitchgearDesign for the Web  
USO GRATIS SwitchgearDesign para a Web  

SUGGESTION TO IEC:   Service to clarify QUESTIONS ABOUT THE INTERPRETATION OF TESTING REQUIREMENTS  

 
The ELECTRIC SHOWER for DOMESTIC USE: An example of WASTE OF RESOURCES by ACCELERATED AGING (with a comment on speech of Bill Gates, to world leaders, at the April’s 2021 “Leaders’ Summit on Climate”)  

O CHUVEIRO ELETRICO DE USO DOMÉSTICO
Um caso de desperdício de recursos  por envelhecimento acelerado 

(com um comentário ao discurso de  Bill Gates, aos líderes mundiais, no April’s 2021 “Leaders’ Summit on Climate”)

 
Environmental Efficiency Certificate  
Certificado de Eficiencia Ambiental  
Project: Testing lab + Simulations  
Projeto: Laboratorio testes + Simulações  
TESTING LABORATORY + DESIGN of SUBSTATION equipment (looking for partners - investors)  
LABORATORIO de TESTES e PROJETO de equipamentos de SUBESTAÇÕES (procuro sócios - investidores)  
   
SUGGESTIONS for IMPROVEMENTS in some IEC STANDARDS: IEC 62271-200, IEC 61439, IEC 60282 , ..About overpressure measurements in IEC 62271-200, temperature rise limits and internal arc in IEC61439, aging test in IEC 60282 , a new T.R. on testing simulations, standards in more languages & new T.R. on design of (lower cost) LV to HV products.  
   
PANELS, SWITCHBOARDS & BUSWAYS DESIGN: copy-paste or improved engineering ?  
Você sabe a razão do blecaute no Amapá ?  
Do you know the reason for the Amapá - Brazil blackout ?  
   
   
Low Cost Substations X Lower Cost of Equipment (It is time to stop kidding with Earth's future)  
SMALL-SIZE HIGH POWER TESTING LABS & LOW-COST SUBSTATIONS (an idea for the new moment of the electric industry)  
The Future of High Power Testing Laboratories  
Book “Switchgear, Busways, Isolators - Substations & Lines”  (available also  in Spanish and Portuguese)
 

IEC 61439: The Mystery of the Temperature Rise Limits

(• Was your low voltage switchgear approved in the temperature rise test? • Is this written in the test report or you have a “quality system” weak point? • An alert to low-voltage switchgear buyers )

 



 An aIEC 61439-1:  Answer to  a   NIAZ  QUESTION in LinkedIn   about TABLE 6 (Limits of temperature rise used in the test).lert to low-voltage switchgear buyers )

 



Four Ideas about Switchboards and Switchgear

(IEC 62271 / 61439: innovations in design, testing and qualification)

 

 

Small high-power testing lab + Simulations(an idea to boost the electrical industry in developing countries)  

 

Accepting Simulations To Replace High Power Tests (An Idea For Developing Countries Without Laboratories)  

 

TRIAXIAL high current AIS - GIS:     disclosing an idea worldwide use !,

In this article I disclose an idea for an alternative design to be used in “air insulated switchgear” (AIS) and “gas insulated switchgear” (GIS).

 

 

 
Co-author of the Cigre Brochure 740 (August 2018) - Contemporary  Design  Of  Low  Cost Substations In Developing Countries )
 

 

IEC 61439 connections: temperature rise of 10K above IEC limit = loss of life 66%

 

 

How can IEC standards help to reduce the gap between developed and developing countries?)
 
 
Certification&Qualification of Electric Products Using “testing simulations”to reduce costs.  

 

Thermodynamic Models and Three-Dimensional Analysis for Loading Transformer Limits Determination  

Power Transformers & Reactors: Calculations of Electromechanical Forces & Stresses, Temperature Rise And Overpressures Of Internal Arc: Method and Possibilities of a Software for Developing Countries

 

Temperature Rise Tests in IEC 61439-1: Low-voltage switchgear - Doubts and ideas to IEC)
 

Finding the Optimal Design using Simulations (Aluminum x Copper)

(Try to do it with real lab high power tests! 

 

 
Finding the Optimal Switchgear Design: A comparison between aluminum and copper and an idea of new concept.  - Co-authors: Sergio Feitoza Costa & Marlon Campos - Also published in Portuguese Jan – 2014 in O SETOR ELÉTRICO “ (page 136)
 
Validation of Magnetic & Electric Fields Mapping & Temperature Rise Tests Simulations (Report 074/2014)
 
Validation of software SwitchgearDesign - Simulation o Tests (Temperature Rise, Short Time Current, Electrodynamic forces, Internal Arc) - Report 071/2014
 
Typical simulation report for high power tests
 
Guide for The Use of Calculations & Simulation of Laboratory Tests
 
Software DECIDIX for the TECHNICAL ECONOMYCAL ASSESSMENT of ENERGY PROJECTS
 
Inducing & Assessing New Technologies for The Electric Industry of Developing Countries
 



Overpressures --Internal Arc Tests: IEC 62271-200 X Cigrè Brochure 602 X IEC 62271-307
 
R&D of Electric Products, Creativity & Costs
 
Design Decisions for Switchgear, Panels, Switchboards & Busways ( & patent)
 
Electrical System Studies: Specification of Equipment for New Substations
 
Interruption of short circuits, electrodynamical forces & temperature rise in substations.
 
Simulation of High Power Tests from 2007 to 2017:  what changed for manufacturers, users, certification companies and testing laboratories?
 
Magnetic & Electric Fields in substations and neighborhood: mapping, health legislation & EMC
 
Typical simulation report for high power tests
 
Brochure CIGRE 602 / 2014 -Tools For The Simulation Of Internal Arc In T&D Switchgear (co-author)
 
Validation of Simulations In Switchgear (& main parts of a code) -CIGRE Technical Seminar "Modeling and Testing of Transmission and Distribution Switchgear" March 24, 2010 Brisbane – Australia
 
Simulation, IEC Standards & Testing Laboratories: Joining Pieces for Higher Quality HV Equipment”.
Paper PS1-06 - CIGRÈ International Technical Colloquium - Rio de Janeiro – September2007
 
Published also in in Energy Pulse weekly, September, 28 , 2010
 
Simulations & Calculations as Verification Tools for Design & Performance of High-Voltage Equipment” . Co-authors: M. Kriegel, X. Zhu, M. Glinkowski, A. Grund, H.K. Kim, P. Robin-Jouan, L. Van der Sluis, R.P.P. Smeets, T. Uchii, H. Digard, D. Yoshida, S. Feitoza Costa -CIGRE publication A3-210 (2008) - Cigre - Paris 2008
 
SIGNIFICANT PARAMETERS IN INTERNAL ARC SIMULATION AND TESTING, - CIGRE WG A3.24, CIGRE A3 SESSION, 2009 - Co-authors: M. Kriegel, R. Smeets, N. Uzelac, R. Pater, M. Glinkowski, P. Vinson, S. Feitoza Costa, G. Pietsch, E. Dullni, Th. Reiher, L. van der Sluis, D. Yoshida, H.K. Kim, K. Y. Kweon, E. Fjeld,
 
IEC Standards for developing countries
 
Validation of Test Reports Issued By Recognized Testing Laboratories
 
Switchgear, Busbar Systems & Built-In Components: Something Is Missing In IEC & IEEE Standards.
 
Also published in Energy Pulse weekly, September, 28 , 2010
 
 
 

EN ESPAÑOLEspañol

     

PANELES ELÉCTRICOS, CELDAS, DUCTOS Y SUBESTACIONES:

ALGUNOS "TRUCOS" PARA MEJORAR SU PROYECTO

 

 

APARAMENTAS, CELDAS, CANALIZACIONESy EQUIPOS para SUBESTACIONES y LÍNEAS

 

 

Pequeño Laboratorio de Alta Potencia + Simulaciones(una idea para impulsar la industria eléctrica de países en desarrollo)  

 

Aceptando Simulaciones Para Reemplazar Pruebas de Alta Potencia (Una Idea Para Países En Desarrollo Sin Laboratorios)

 

 

VALIDACIÓN DEL Software SwitchgearDesign para la simulación de pruebas de alta potencia(corrientes soportables de corta duración y cresta - fuerzas electrodinámicas, calentamientoy sobrepresiones del arco interno)  
Conexiones IEC 61439:aumento de temperatura de 10 K por encima del límite IEC = pérdida de vida 66%  

 

Tableros, Celdas y Aparamentas:
El Diseño Óptimo utilizando Simulaciones (Aluminio X Cobre)

 

 

Certificación y calificación de productos eléctricos  

 


Celdas, Cuadros, Canalizaciones y Otros Equipos de Transmisión y Distribución
 

También publicado en Revista RBE Energía (Madrid / España) - Enero/Febrero 2010 - pag 62

 

Validación De Los Informes De Ensayo Emitidos Por Laboratorios De Pruebas Reconocidos

 

Nuevas Tecnologías Y Procedimientos En La Industria Eléctrica De Países En Desarrollo

 
 

EM PORTUGUES Portugues

   
     

https://www.cognitor.com.br/Book_SE_SW_2013_POR.pdf

 

 

PequenoLaboratóriode Alta Potência+ Simulações(uma ideia para impulsionar a indústriaeléctricade paísesem desenvolvimento)  

 

 

Tabela 6 da  IEC 61439-1:   PERGUNTA a  CERTIFICADORAS  e  LABORATORIOS  :Que limites de elevação de temperatura, em conexões barra / disjuntor, utilizam ao aprovar ou certificar  painel BT ?


Aceitando Simulações para Substituir Testes De Alta Potência (Uma Idéia Para Países em Desenvolvimento Sem Laboratórios)

 

 

IEC 61439: elevação de temperatura nas conexões  

 

Um “Guia” De Uso De Cálculos E Simulações De Ensaios Para Aumento Da Competitividade

 

 

GUIA Orientações para Uso De Simulações para Extrapolar Resultados ou Substituir Alguns Ensaios De Alta Potência Especificados nas Normas ABNT.  

 

Proposta para GUIA ABNT s/ uso de SIMULAÇÕES DE ENSAIOS ELÉTRICOS 8/5/2011  

 

Validação De Relatórios De Ensaios Emitidos Por Laboratórios Reconhecidos – O Setor Eletrico – Ed. 82 – Nov. 2012

 

Novas Tecnologias e Procedimentos para a Indústria Elétrica de Países em Desenvolvimento

 

Painéis, Quadros E Barramentos: Falta Algo Nas Normas IEC - O Setor Elétrico - junho 2010  - pág. 146

 

Validação De Simulações De Ensaios De Arco Interno, De Forças Eletrodinâmicas E De Elevação De Temperatura - Junho 2010 -Eletricidade Moderna - pág. 194

 

Software Livre Decidix Para Avaliação Da Viabilidade De Projetos De Energia (Geração, Cogeração, T&D)

 
 

Artigos publicados na Revista Setor Elétrico (Janeiro a Dezembro 2015)

Capítulo I – Definições e estudos do sistema elétrico que servem de base para as especificações técnicas dos equipamentos para subestações de transmissão e distribuição

 

Capítulo II – Curtos-circuitos, ampacidades sobrecargas e contatos elétricos.

 

Capítulo III (março): Técnicas de ensaios de alta potência, laboratórios e fundamentos dos ensaios

 

Capítulo IV (abril):  Estudos elétricos de sobretensões, coordenação de isolamento e impactos de campos elétricos e magnéticos

 

Capítulo V (maio): Arcos internos em equipamentos de subestações

 

Capítulo VI (junho): Especificações técnicas de disjuntores, secionadores, painéis e para-raios feitas por concessionárias de energia

 

Capítulo VII (Julho) – Distancias de segurança de subestações e sistemas de proteção contra incêndios em subestações 

 

Capitulo VIII (Agosto): Novos conceitos utilizados no Relatório Técnico IEC 62271-307 (painéis de media tensão)

 

Capitulo IX (Setembro): Técnicas Para Reformar Eqiuiamentos De Subestações E Adiar Investimentos.

 

Capitulo X: (Outubro): Induzindo novas tecnologias para o setor elétrico (Novas Tecnologias para 145 kV)

 

Capitulo XI (Novembro): Cálculo da elevação de temperatura em invólucros pela IEC 60890

 

Capitulo XII (Dezembro): Cálculos de Engenharia em Projetos de Equipamentos para Subestações

 

 

OTHER OLDER PUBLICATIONS

 

Back to the top *** Voltar ao topo

 

TITLE AND NAME OF AUTHOR ( THESIS, ARTICLES, PATENTS - ABOUT SUBSTATIONS AND THEIR EQUIPMNT

E-mail

Web link

M.Sc. Thesis – 1979 – COPPE - UFRJ: Electromechanical stresses in electrical equipment, especially switchgear & busbar systems.
By Sergio F. Costa  

sergiofeitozacosta@gmail.com

https://www.cognitor.com.br